What is the max # of 7921's we can connect to a 48 user UC520? In other words, we need to connect 11 7921's to a UC520, can this be done? We will get 2 WLAN controllers and AP's as needed for this design. Thanks - John |
|||
|
UC500.comCisco Communication Manager Express, UC520, SMB VOIP reference and community |
Q. What is the max # of
Q. What is the max # of 7921's we can connect to a 48 user UC520?
A. 48
Q. How many Cisco Unified Wireless IP Phone 7921s can co-exist per access point?
A. It is recommended that no more than seven co1ncurrent G.711 calls, or eight concurrent G.729 calls, be active on an access point. The number of inactive Cisco Unified Wireless IP Phone 7921s that are registered with an access point is recommended to not exceed 15 to 20. This is in line with the recommended number of wireless endpoints (clients) supporting only data traffic.
- Dapunnisher, CCVP